SUROVTSEV I.V. 1DSc (Engineering), Senior Researcher,
Head of the Department of Digital Systems for Ecological Monitoring
https://orcid.org/0000-0003-1133-6207, e-mail: igorsur52@gmail.com
SAVCHENKO-SYNIAKOVA Ye.A. 1 PhD (Engineering),
Senior Researcher of the Department of Information Technologies for Inductive Modeling
https://orcid.org/0000-0003-4851-9664, e-mail: savchenko_e@meta.ua
GALIMOVA V.M. 2 PhD (Chem.),
Associate Professor of the Department of Analytical and Bioinorganic Chemistry and Water Quality
https://orcid.org/0000-0001-9602-1006, e-mail: galimova2201@gmail.com
LIAKHOV V.S. 1 PhD Student,
https://orcid.org/0009-0004-5332-1104 , e-mail: vlyahov@gmail.com
YAKOVENKO I.M. 1,
Researcher of the Intellectual Automatic Systems Department
https://orcid.org/0000-0002-4477-3254, e-mail: yakvan@ukr.net
1 International Research and Training Center for Information Technologies
and Systems of the National Academy of Sciences of Ukraine
and the Ministry of Education and Science of Ukraine
40, Acad. Glushkov av., Kyiv, 03187, Ukraine
2 National University of Life and Environmental Sciences of Ukraine,
19 building 1, of.12, Horikhuvatskyi shliakh Str., Kyiv, 03041, Ukraine
APPROACHES TO THE DEVELOPMENT OF INFORMATION TECHNOLOGY FOR RAPID IDENTIFICATION OF THE ENVIRONMENTAL OBJECTS ECOLOGICAL STATE
Introduction. The task of express measurement of water pollution is a pressing issue of the 20th century. Development of methods and, based on them, technologies and devices that are easy to use and affordable will allow determining the concentration of toxic substances in water in order to assess its quality. The use of fast systems for determining the ecological state of water bodies will help reduce the risk of consuming contaminated water.
The purpose of the paper is to analyze approaches to express measurement of the concentration of toxic substances in water to develop approaches to building an information technology for rapid assessment of water quality.
Results. An analysis of approaches to express measurement of the concentration of toxic substances in water was conducted. A review of methods for determining the concentration of toxic substances in water was conducted. The development of electrochemical methods of analysis and the use of various sensors for determining the concentrations of individual elements were studied, approaches to the development of practical automated systems for electrochemical studies and the features of the use of information technologies for processing analytical signals were considered.
Conclusions. The conducted analysis showed that it is advisable to measure the concentrations of toxic elements lead, cadmium, copper, zinc, phosphorus in water using pulse methods of inversion chronopotentiometry and sensors made of noble metals.
Keywords: information technology, hardware and software complex, methods of analysis, water pollution, express measurement, heavy metals, concentration of toxic substances/ assessment of quality, modeling, identification, monitoring, automated system.
REFERENCES
1. Council Directive 98/83/EC of 3 November 1998 on the quality of water intended for human consumption OJL 330, 5.12.1998, p. 32. URL: https://eur-lex.europa.eu/legal-content/EN/TXT/PDF/?uri=CELEX:01998L0083-20151027&from=EN.
2. Hygienic requirements for drinking water intended for human consumption. Order of the Ministry of Health of Ukraine dated 12.05.2010 No.400. Register. July 1, 2010 for No. 452/17747 (in Ukrainian).
3. Briffa J., Sinagra E., Blundell R. Heavy metal pollution in the environment and their toxicological effects on humans. 2020, Heliyon, 6, No. e04691
https://doi.org/10.1016/j.heliyon.2020.e04691
4. Liu F., Zhang, Z. Zhang, L. Meng, R.N., Gao J., Jin M., Li M., Wang X.P. Effect of metal ions on Alzheimer’s disease. Brain Behav. 2022, 12, e2527.
https://doi.org/10.1002/brb3.2527
5. Pinheiro J.P., Rotureau E. (2023). Electroanalytical trace metal cations quantification and speciation in freshwaters: historical overview, critical review of the last five years and road map for developing dynamic speciation field measurements. Molecules, 28 (6), 2831.
https://doi.org/10.3390/molecules28062831
6. Sokolkov S.V. Evolution of the analytical signal in electrochemistry from electrocapillary curve to a digital electrochemical pattern of a multicomponent sample. Electrochemical. 2023, 3 (3), p. 1-17.
https://doi.org/10.1002/elsa.202100212
7. Qian W.U., Hong-Mei B.I., Xiao-Jun Han. (2021). Research Progress of Electrochemical Detection of Heavy Metal Ions. Chinese Journal of Analytical Chemistry. Volume 49, Issue 3, pp. 330-340,
https://doi.org/10.1016/S1872-2040(21)60083-X
8. Xu F., Wang P., Bian S., Wei Y., Kong D., Wang H.A. (2021). Co-Nanoparticles Modified Electrode for On-Site and Rapid Phosphate Detection in Hydroponic Solutions. Sensors. 2021, 21, 299.
https://doi.org/10.3390/s21010299
9. Hu T., Lai Q., Fan W., Zhang Y., Liu Z. Advances in Portable Heavy Metal Ion Sensors. Sensors. 2023, 23, 4125.
https://doi.org/10.3390/s23084125
10. Wang Y., Zhai H.G., Yin J.Q., Guo Q., Zhang Y.H., Sun X., Guo, Y.M., Yang Q.Q., Li F.L., Zhang Y.Y. Recent advances and future prospects of aptamer-based biosensors in food safety analysis. Int. J. Electrochem. Sci., 2022, 17, 22019.
https://doi.org/10.20964/2022.01.07
11. Pham V.H.T., Kim J., Chang S., Chung W.. Bacterial biosorbents, an efficient heavy metals green clean-Up strategy: Prospects, challenges, and opportunities. Microorganisms. 2022, 10, 610.
https://doi.org/10.3390/microorganisms10030610
12. Fan M.K., Andrade G.F.S., Brolo A.G. A review on recent advances in the applications of surface-enhanced Raman scattering in analytical chemistry. Anal. Chim. Acta. 2020, 1097, pp.1-29.
https://doi.org/10.1016/j.aca.2019.11.049
13. Zeitoun R., Biswas A. Review-Potentiometric Determination of Phosphate Using Cobalt: A Review. J. Electrochem. Soc. 2020, 167.
https://doi.org/10.1149/1945-7111/abad6c
14. Li W., Zu B., Yang Q.W., Huang Y.Q., Li J.W. Adsorption of lead and cadmium by microplastics and their desorption behavior as vectors in the gastrointestinal environment. J. Environ. Chem. Eng. 2022, 10, 107379.
https://doi.org/10.1016/j.jece.2022.107379
15. Ghosh S., Dissanayake K., Asokan S., Sun T., Rahman B.M.A., Grattan K.T.V. Lead (Pb2+) ion sensor development using optical fiber gratings and nanocomposite materials. Sens. Actuators B-Chem. 2022, 364, 131818.
https://doi.org/10.1016/j.snb.2022.131818
16. Wang S.-L., Hsieh C.-Y., Sukesan R., Chen J.-C., Wang Y.-L. Highly sensitive lead ion detection in one drop of human whole blood using impedance-modulated field-effect transistors and a portable measurement device. ECS J. Solid State Sci. Technol. 2020, 9, 055020.
https://doi.org/10.1149/2162-8777/ab8867
17. Gupta A.K., Khanna M., Roy S., Pankaj Nagabooshanam, S. Kumar, R. Wadhwa S., Mathur, A. Design and development of a portable resistive sensor based on alpha-MnO2/GQD nanocomposites for trace quantification of Pb(II) in water. IET Nanobiotechnol. 2021, 15, 505-511.
https://doi.org/10.1049/nbt2.12042
18. Solomonea B.G., Jinga L.I., Antohe V.A., Socol G., Antohe I. Cadmium ions’ trace-Level detection using a portable fiber optic-surface plasmon resonance sensor. Biosensors. 2022, 12, 573 p.
https://doi.org/10.3390/bios12080573
19. Kopilevich V.A., Maksin V.I., Galimova V.M., Surovtsev I.V., Lavrik R.V. (2021). Electrochemical Control of Microconcentrations of Cadmium in Aquatic Environments. Journal of water chemistry and technology. 2021, 43 (4), 336-341.
https://doi.org/10.3103/S1063455X21040056
20. Gerdan Z., Saylan Y., Denizli A. Recent advances of optical sensors for copper ion detection. Micromachines. 2022, 13, 1298.
https://doi.org/10.3390/mi13081298
21. Snigur D., Chebotarev A., Bulat K., Duboviy V. Fast room temperature cloud point extraction procedure for spectrophotometric determination of phosphate in water samples. Anal. Biochem. 2020, 597, 113671.
https://doi.org/10.1016/j.ab.2020.113671
22. Salem, J.K., Draz, M.A. Selective colorimetric nano-sensing solution for the determination of phosphate ion in drinking water samples. Int. J. Environ. Anal. Chem. 2020, pp.1-10.
https://doi.org/10.1080/03067319.2019.1702168
23. Tuan V.N., Dinh T.D., Khattak A.M., Zheng L., Chu X., Gao W., Wang M. Multivariate Standard Addition Cobalt Electrochemistry Data Fusion for Determining Phosphate Concentration in Hydroponic Solution. IEEE Access. 2020, 8, 28289-28300.
https://doi.org/10.1109/ACCESS.2020.2971143
24. Noorhashimah M.N., Siti N.N., Nor D.Z., Khairunisak A.R. Simultaneous Sensing of Cd(II), Pb(II), and Cu(II) Using Gold Nanoparticle-Modified APTES-Functionalized Indium Tin Oxide Electrode: Effect of APTES Concentration. ACS Omega. 2023, No 8, 16587−16599. https://pubs.acs.org/doi/10.1021/acsomega.2c07085
https://doi.org/10.1021/acsomega.2c07085
25. Pudza M.Y., Abidin Z.Z., Abdul-Rashid S., Yasin F.M., Noor A.S.M., Abdullah J. Selective and simultaneous detection of cadmium, lead and copper by tapioca-derived carbon dot−modified electrode. Environ. Sci. Pollut. Res. 2020, 27, 13315−13324.
https://doi.org/10.1007/s11356-020-07695-7
26. Lu Z., Zhang J., Dai W., Lin X., Ye J., Ye J. A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II). Microchim. Acta. 2017, 184, 4731−4740.
https://doi.org/10.1007/s00604-017-2521-8
27. Hackel L., Rotureau E., Morrin A., Pinheiro J.P. Developing On-Site Trace Level Speciation of Lead, Cadmium and Zinc by Stripping Chronopotentiometry (SCP): Fast Screening and Quantification of Total Metal Concentrations. Molecules. 2021, 26, 5502.
https://doi.org/10.3390/molecules26185502
28. Li D.J., Sun Y., Shen Q.R., Zhang Q., Huang W., Kang Q., Shen D.Z. Smartphone-based three-channel ratiometric fluorescent device and application in filed analysis of Hg2+, Fe3+ and Cu2+ in water samples. Microchem. J. 2020, 152, 104423.
https://doi.org/10.1016/j.microc.2019.104423
29. Zhou Y., Wang H.L., Song D., Li Z.G., Han S.T., Long F., Zhu A.N. Simple, rapid, and sensitive on-site detection of Hg2+ in water samples through combining portable evanescent wave optofluidic biosensor and fluorescence resonance energy transfer principle. Anal. Chim. Acta. 2021, 1155, 338351.
https://doi.org/10.1016/j.aca.2021.338351
30. Zhang H.J., Wang D., Zhang D., Zhang T.T., Yang L.K., Li Z.P. In Situ Microfluidic SERS Chip for Ultrasensitive Hg2+ Sensing Based on I-Functionalized Silver Aggregates. Acs Appl. Mater. Interfaces. 2022, 14, 2211-2218.
https://doi.org/10.1021/acsami.1c17832
31. Rotake D.R., Kumar A., Darji A.D., Singh J. Highly selective sensor for the detection of Hg2+ions using homocysteine functionalised quartz crystal microbalance with cross-linked pyridinedicarboxylic acid. IET Nanobiotechnol. 2020, 14, p. 563-573.
https://doi.org/10.1049/iet-nbt.2020.0109
32. Ferrari A.G.M., Crapnell R.D., Adarakatti P.S., Suma B.P., Banks C.E. Electroanalytical overview: The detection of chromium. Sens. Actuators Rep. 2022, 4, 100116.
https://doi.org/10.1016/j.snr.2022.100116
33. Hu H., Xie B., Lu Y., Zhu J. Advances in electrochemical detection electrodes for As3+. Nanomaterials. 2022, 12, 781.
https://doi.org/10.3390/nano12050781
34. Sharma P., Bhogal S., Mohiuddin I., Yusuf M., Malik A.K. Fluorescence “turn-off” sensing of iron (III) Ions utilizing pyrazoline based sensor: Experimental and computational study. J. Fluoresc. 2022, 32, 2319-2331.
https://doi.org/10.1007/s10895-022-03024-y
35. Baranwal J., Barse B., Gatto G., Broncova G., Kumar A. Electrochemical sensors and their applications: A review. Chemosensors. 2022, 10, 363 p.
https://doi.org/10.3390/chemosensors10090363
36. Qin M., Li J.S., Song Y.L. Toward high sensitivity: Perspective on colorimetric photonic sensors. Anal. Chem., 94, 9497-9507.
https://doi.org/10.1021/acs.analchem.2c01804
37. He Y.Y.; Wang Y.B., Mao G.N., Liang C.Y., Fan M. Ratiometric fluorescent nanoprobes based on carbon dots and multicolor CdTe quantum dots for multiplexed determination of heavy metal ions. Anal. Chim. Acta. 2022, 1191, 339251.
https://doi.org/10.1016/j.aca.2021.339251
38. Chen Z.L., Xie M.J., Zhao F.G., Han S.Y. Application of Nanomaterial Modified Aptamer-Based Electrochemical Sensor in Detection of Heavy Metal Ions. Foods. 2022, 11, 1404.
https://doi.org/10.3390/foods11101404
39. Ali, T.A.; Mohamed, G.G. Development of Chromium(III) Selective Poten tiometric Sensors for Its Determination in Petroleum Water Samples Using Synthesized Nano Schiff Base Complex as an Ionophore. J. Aoac Int. 2022, 105, 727-738.
https://doi.org/10.1093/jaoacint/qsab166
40. Tian H.; Li, Z.M.; Wang C.Z.; Xu P.; Xu S.F. Construction and application of molecularly imprinted fluorescence sensor. Prog. Chem. 2022, 34, 593-608.
41. Wang B.T.; Niu Y.X.; Yang Y.; Liang T.; Qin X.D.; Ding M. Sapphire Fiber High-Temperature Sensor Based on Colorimetric Method. IEEE Trans. Instrum. Meas. 2022, 71, 9508506.
https://doi.org/10.1109/TIM.2022.3189738
42. He, X.; Zhou, X.; Liu, Y.; Wang, X.L. Ultrasensitive, recyclable and portable microfluidic surface-enhanced raman scattering (SERS) biosensor for uranyl ions detection. Sens. Actuator B-Chem. 2020, 311, 127676.
https://doi.org/10.1016/j.snb.2020.127676
43. Liang Y.; Ma M.; Zhang F.; Liu F.; Lu T.; Liu Z.; Li Y. (2021). Wireless Microfluidic Sensor for Metal Ion Detection in Water. ACS Omega. 2021, 6, 9302-9309.
https://doi.org/10.1021/acsomega.1c00941
44. Nguyen M. B.; Nga D. T. N.; Thu V. T.; Piro B.; Truong T. N. P.; Yen P. T. H.; Le G. H.; Hung L. Q.; Vu T. A.; Ha V. T. T. Novel nanoscale Yb-MOF used as highly efficient electrode for simultaneous detection of heavy metal ions. J. Mater. Sci. 2021, 56, 8172−8185. https://doi.org/10.1007/с10853-021-05815-3
https://doi.org/10.1007/s10853-021-05815-3
45. Mohamad Nor N.; Ramli N. H.; Poobalan H.; Qi Tan K.; Abdul Razak K. Recent. Advancement in Disposable Electrode Modified with Nanomaterials for Electrochemical Heavy Metal Sensors. Crit. Rev. Anal. Chem. 2023, 53, 253.
https://doi.org/10.1080/10408347.2021.1950521
46. Silah H.; Erkmen C.; Demir E.; Uslu B. Modified indium tin oxide electrodes: Electrochemical applications in pharmaceutical, biological, environmental and food analysis. TrAC, Trends Anal. Chem. 2021, 141, No. 116289.
https://doi.org/10.1016/j.trac.2021.116289
47. Eswaran M.; Tsai P.-C.; Wu M.-T.; Ponnusamy V. K. Novel nano-engineered environmental sensor based on polymelamine/ graphitic-carbon nitride nanohybrid material for sensitive and simultaneous monitoring of toxic heavy metals. J. Hazard. Mater. 2021, 418, No. 126267.
https://doi.org/10.1016/j.jhazmat.2021.126267
48. Dutta S.; Strack G.; Kurup P. Gold nanostar electrodes for heavy metal detection. Sens. Actuators. 2019, B, 281, p.383−391.
https://doi.org/10.1016/j.snb.2018.10.111
49. Katiyar R.; Usha Rani K.R.; Sindhu T.S.; Sneha Jain H.D.; Vidhyashree; Ashoka S.; Channegowda M. Design and development of electrochemical potentiostat circuit for the sensing of toxic cadmium and lead ions in soil. Eng. Res. Express. 2021, 3, 045026.
https://doi.org/10.1088/2631-8695/ac3637
50. Ngoc Tuan V.; Khattak A.M.; Zhu H.; Gao W.; Wang M. Combination of Multivariate Standard Addition Technique and Deep Kernel Learning Model for Determining Multi-Ion in Hydroponic Nutrient Solution. Sensors. 2020, 20, 5314.
https://doi.org/10.3390/s20185314
51. Mukherjee S.; Bhattacharyya S.; Ghosh K.; Pal S.; Halder A.; Naseri M.; Mohammadniaei M.; Sarkar S.; Ghosh A.; Sun, Y. Sensory development for heavy metal detection: A review on translation from conventional analysis to field-portable sensor. Trends Food Sci. Technol. 2021, 109, p. 674-689.
https://doi.org/10.1016/j.tifs.2021.01.062
52. Wang H.L.; Song D.; Chen Y.Y.; Xu W.J.; Han X.Z.; Zhu A.N.; Long F. Development of portable whole-cell biosensing platform with lyophilized bacteria and its application for rapid on-site detection of heavy metal toxicity without pre-resuscitation. Anal. Chim. Acta. 2022, 1228, 340354.
https://doi.org/10.1016/j.aca.2022.340354
53. Li B.H.; Wang J.H.; Tu H.H.; Yang Z.J.; Zhao D.F.; Feng H.H.; Yang J. A self-designed versatile and portable sensing device based on smart phone for colorimetric detection. Anal. Bioanal. Chem. 2021, 413, p. 533-541.
https://doi.org/10.1007/s00216-020-03024-6
54. Bernalte E.; Arévalo S.; Pérez-Taborda J.; Wenk J.; Estrela P.; Avila A.; Di Lorenzo M. Rapid and on-site simultaneous electrochemical detection of copper, lead and mercury in the Amazon river. Sens. Actuators. 2020, B, 307, No. 127620.
https://doi.org/10.1016/j.snb.2019.127620
55. Analyzer of heavy metals. Jiangsu Skyray Instrument Co, China. Available at: https://www.sky-rayinstrument.com/heavy-metal-analyzer/portable-heavy-metal-analyzer.html
56. 946 Portable VA Analyzer (SPE). URL: https://www.metrohm.com/en/products/2/9460/ 29460020.html
57. Pinheiro J.P., Galceran J., Rotureau E., Companys E., Puy J. Full wave analysis of stripping chronopotentiometry at scanned deposition potential (SSCP): Obtaining binding curves in labile heterogeneous macromolecular systems for any metal-to-ligand ratio. J. Electroanal. Chem. 2020, 873, 114436,
https://doi.org/10.1016/j.jelechem.2020.114436
58. Surovtsev I.V., Velykyi P.Y., Hrytsaienko M., Galimova V.M. Analitical system for environmental monitoring and risk assessing of drinking water consumption. Cyb. and comp. eng. 2021. no. 4 (206), 17-38.
https://doi.org/10.15407/kvt206.04.017
59. Wang L., Yang D., Lamb D., Chen Z., Lesniewski P.J., Megharaj M., Naidu R. Application of mathematical models and genetic algorithm to simulate the response characteristics of an ion selective electrode array for system recalibration. Chemom. Intell. Lab. Syst. 2015, 144, p. 24-30.
https://doi.org/10.1016/j.chemolab.2015.03.007
60. Mueller A.V., Hemond H.F. Extended artificial neural networks: Incorporation of a priori chemical knowledge enables use of ion selective electrodes for in-situ measurement of ions at environmentally relevant levels. Talanta. 2013, 117, p. 112-118.
https://doi.org/10.1016/j.talanta.2013.08.045
61. Surovtsev, I.V., Galimov, S.K., Tatarinov, O.E. Information Technology for Determining the Concentration of Toxic Elements in Environmental Objects. Kibern. vyčisl. teh. 2018, no 191, p. 5-31. DOI:https://doi.org/10.15407/kvt191.01.005
https://doi.org/10.15407/kvt191.01.005
62. Device for measuring the concentration of chemical elements by pulsed chronopotentiometry: patent 123459, Ukraine: IPC G01N 27/48 (2006.01), a201902429; claimed 12.03.2019; published 07.04.2021 (in Ukrainian).
63. Babak O.V., Surovtsev I.V. Data Reduction as a Method of Intellectualization of Information Technologies. Cyb. and comp. eng. 2022, no. 1 (207), p. 17-31.
https://doi.org/10.15407/kvt207.01.018
64. Surovtsev I.V., Sieriebriakov A.K. Method of elements identification in the multicomponent signal. Control Systems and Computers. 2023, no. 2, 19-26. DOI: https://doi.org/10.15407/csc.2023.02.019
https://doi.org/10.15407/csc.2023.02.019
65. Kozak L.M., Kovalenko O.S., Surovtsev I.V. Basic components of the software modules construction for obtaining, storing and exchanging medical and environmental information. Cybernetics and computer engineering. 2023, 3 (213), 53-68.
https://doi.org/10.15407/kvt213.03.053
Received 12.09.2024